Power Supply Unit; Hot Spare Feature; Removing A Power Supply Unit Blank - Dell PowerEdge R960 Installation And Service Manual

Table of Contents

Advertisement

Next steps
1. If removed,
install the
2.
Install the riser air
shroud.
3.
Install the expansion card risers
4.
Install the air shroud
5.
Install the cooling fan cage
6.
Install the air shroud top
7.
Install the support
bar.
8. Follow the procedure listed in

Power supply unit

NOTE:
While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same
firmware and configuration of the replaced one. For updating to the latest firmware and changing the configuration, see the
Lifecycle Controller User's Guide at https://www.dell.com/idracmanuals.

Hot spare feature

Your system supports the hot spare feature that significantly reduces the power overhead associated with the power supply
unit (PSU) redundancy.
When the hot spare feature is enabled, one of the redundant PSUs is switched to the sleep state. The active PSU supports 100
percent of the system load, thus operating at higher efficiency. The PSU in the sleep state monitors output voltage of the active
PSU. If the output voltage of the active PSU drops, the PSU in the sleep state returns to an active output state.
If having both PSUs active is more efficient than having one PSU in the sleep state, the active PSU can also activate the
sleeping PSU.
The default PSU settings are as follows:
● If the load on the active PSU is more than 50 percent of PSU rated power wattage, then the redundant PSU is switched to
the active state.
● If the load on the active PSU falls below 20 percent of PSU rated power wattage, then the redundant PSU is switched to
the sleep state.
You can configure the hot spare feature by using the iDRAC settings. For more information, see the iDRAC User's Guide
available at www.dell.com/poweredgemanuals.

Removing a power supply unit blank

Prerequisites
Follow the safety guidelines listed in the
Steps
Pull the blank out of the system.
CAUTION:
To ensure proper system cooling, the PSU blank must be installed in the empty PSU bay in a non-
redundant configuration. Remove the PSU blank only if you are installing a PSU.
PEM.
or
Install the full length expansion card
assembly.
cover.
After working inside your
Safety
instructions.
riser.
system.
Installing and removing system components
185