Supported Fiber Optic Cables - Siemens RUGGEDCOM RS8000T Installation Manual

Hide thumbs Also See for RUGGEDCOM RS8000T:
Table of Contents

Advertisement

RUGGEDCOM RS8000T
Installation Guide
that during a transient electrical event, communications errors or interruptions may occur, but recovery is
automatic.
Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across
distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground
fault conditions.
CONTENTS
Section 1.5.1, "Supported Fiber Optic Cables"
Section 1.5.1

Supported Fiber Optic Cables

The following fiber optic cable types are supported under the stated conditions.
Cable Type
OM1 (62.5/125)
OM2 (50/125)
a
OM3 (50/125)
a
OM4 (50/125)
a
Laser optimized.
Supported Fiber Optic Cables
Modal Bandwidth
Wavelength (nm)
(MHz·km)
850
1300
850
1300
850
1300
850
1300
100Base-FX
200
500
2000
500
500
2000
1500
500
2000
3500
500
2000
Introduction
Distance (m)
1000Base-SX
10GBase-SR
275
33
550
82
550
300
550
400
Chapter 1