3. INITIAL SETTINGS
4. Select [Device List] to show the list of other connected equipments and press the
KNOB. Select the device from the list and press the KNOB to show the [Device
Info] display.
Device List
Refresh
PG-700
[MENU]
Adjust the value of [Device Instance] and [System Instance].
Note: To see the latest information, select [Refresh] on the [Device List] window.
5. Select [Incoming PGN] and press the KNOB to show status of NMEA2000 incom-
ing PGN list. Received data is displayed in black, while data not yet received is
displayed in gray (updated in one-second cycles). The middle section of the win-
dow shows the information of the PGN selected by the selection cursor (shown in
yellow).
PGN information
6. Select [NMEA Output] and press the KNOB to adjust what data sentences to out-
put.
• [Off]: Do not output the 128259, 128267, 130310, 130312, 130316, 130830,
130831, 130832 PGN data sentences.
• [On]: Output the 128259, 128267, 130310, 130312, 130316, 130830, 130831,
130832 PGN data sentences.
7. Press the MENU/ESC key twice to close the menu.