6. Attach the transducer to the hull.
Press the transducer firmly down on the hull and gently twist it back and forth to
remove any air which may be trapped in the marine sealant.
Hull
7. Support the transducer with a piece of wood to keep it in place while the sealant
is drying. It takes 24-72 hours to harden completely.
8. Turn the power on and change the menu setting as follows:
1) Press the MENU/ESC key to show the main menu.
2) Select [Sounder] menu and press the KNOB.
3) Select [TX Power] and press the KNOB.
4) Select [5] and press the KNOB.
5) Press the MENU/ESC key.
6) Select [Calib] from the [System] menu and press the KNOB.
7) Select the [Gain ADJ CHIRP HF/MF/LF], [Gain ADJ CW HF/ LF] as desired
and press the KNOB. Menu items are displayed according to the connected
transducer.
8) Set the value as ''+20'' and press the KNOB.
9) If multiple CW/CHIRP transducers are shown, repeat step 7.
10) For FCV-600, select [Bottom Level XDR] and press the KNOB. For FCV-800,
select [Bottom Level XDR1] and press the KNOB.
11) Set the bottom level value as ''-40'' and press the KNOB.
12) If two transducers are connected, repeat step 10 and select [Bottom Level
XDR2] to set the value (for FCV-800 only).
13) Press the MENU/ESC key two times to close the menu.
Marine
sealant
14
1. MOUNTING