2.1.3
NMEA2000 device connection
Use the optional FRU-NMEA-PMMFF cable (1m, 2m, 6m, both end connectors) or
FRU-NMEA-PFF (1m, 2m, 6m, single end connector) to connect to the backbone of
NMEA2000 (CAN bus) network. The NMEA2000 device must be connected to the
same backbone as the NMEA2000 devices (GPS receiver and Satellite Compass™)
used as data sources for the monitoring system.
FRU-MM1MF1MF1001 Option
Terminator
NMEA2000 Device
GPS Receiver
Note 1: NMEA2000 corresponds to CAN bus, so CAN bus devices can also be con-
nected.
Note 2: The NMEA2000 (CAN bus) network requires a dedicated NMEA2000 power
supply. Turn on the power for the NMEA2000 network before turning on the system.
Note 3: Terminators must be installed at both ends of the backbone cable of the
NMEA2000 (CAN bus) network. The following table shows the optional terminators
available for the NMEA2000.
Name
Connector
(NMEA)
Jumper block setting
Transducer
J2: No output reduction (default)
50B-6/6B
J1: Output reduction
50kHz
J2
TB2
SHIELD
1
RED
2
RED
3
BLK
200kHz
4
BLK
5
Detach grommet;
Transducer
attach cord lock.
200B-5S
FCV-800
T Connector
NMEA2000 CAN bus Backbone
Type
FRU-MM1000000001
FRU-MF000000001
02P6348
Green
J1
(shield)
TB1
WHT
3
2
1
BLK
Connect 10P
connector to
XDR port on
rear of
display unit.
FRU-NMEA-PMMFF Cable, FRU-NMEA-PFF Cable
1/2/6m, Option
NMEA2000 Device
Satellite Compass
Code No.
001-507-070
001-507-060
24
2. WIRING
Terminator
TM
Remarks
Male
Female