2. WIRING
Dual frequency CHIRP transducer connection*.
Compatible transducers: B265LH-FJ12, TM265LH-FJ12,
CM265LH-FJ12, etc.
Simultaneous connection of single frequency (LF) CHIRP and single
frequency (MF/HF) CHIRP transducers.
Compatible transducers: Only in the below combinations
• LF: B-75L, MF: B150M/B75M, HF: B-75H
• LF: SS75L, MF: SS75M, HF: SS75H
• LF: B-175L, MF: B175M, HF: B-175H/B175HW
Simultaneous connection of CW and single frequency (MF/HF) CHIRP
transducers.
Compatible transducers: See above.
Note: Simultaneous connection of CW and single frequency (LF)
CHIRP transducers is not available.
*:When connecting dual frequency CHIRP transducer, an optional cable assembly
(type: FRU-MJ10CCB12-300) is required.
Note: When using the optional extension cable (for 10-pin: C332 10M, for 12-pin:
FRU-CCB12-DA-10M), keep the following points in mind.
• Detection performance may be degraded.
• False positives (under-display of fish length, reduced number of detections, false
detection of single fish) may occur when using the ACCU-FISH™ function.
• Values measured by the ship speed sensor may differ from the actual values.
• TD-ID may not work.
Matching box for 1kW transducer
The optional matching box (type: MB-1100) is required to connect the 1kW transduc-
ers (however, for 526TID-HDD matching box is not required).
Part
Matching Box*
Crimp-on Lug
Cord Lock**
*: With 10P connector cable
**: For connecting two transducers
Connect the transducer cables to the matching box as shown below.
Transducer
Type
MB-1100
000-027-226
FV1.25-3 (LF)
000-116-756-10
NC-1
000-168-230-10
Vinyl sheath
Taping
Shrink tubing
23
[XDR1], [XDR2]
[XDR1]: CHIRP (LF)
[XDR2]: CHIRP (MF/HF)
[XDR1]: CW
[XDR2]: CHIRP
Code no.
Qty
Crimp-on lug
FV1.25-3 (LF)
Shield
Connection port
1
6
1