1. MOUNTING
1.2.2
Flush mount (option)
Use the optional flush mount kit to install the unit as shown below.
Note 1: Select a flat mounting location to install the unit.
Note 2: It is recommended to set up a dedicated breaker when flush mounting the unit,
since it will be difficult to disconnect cables.
For FCV-600
The below flush mount kit is required when flush mounting the unit.
1. Use the template (supplied) and cut out a hole in the mounting location.
2. See page 4 to unfasten the two knobs on either side of the main unit to separate
the main unit and a hanger. The knob and hanger can be disposed.
3. Attach the Sponge V and H for Mount F (four in total, supplied) in order at the back
of the unit (see the figure below).
Note 1: Work on a soft cloth to avoid damaging the main unit.
Note 2: Make sure not leave any gap between sponge V and H when attaching.
4. See section 2.1 to connect the required cables to the back of the unit.
5. Fasten the main unit with connected cables to the mounting location.
Flat
Kit details: OP02-89, Code No.: 001-638-230
Mounting template (for both FCV-600 and
FCV-800 (double-sided printing))
Sponge V for F mount
Sponge H for F mount
F mount metal assembly
Slotted Hex Bolt
Curved
Name
,
Sponge H for Mount F
,
Sponge V for Mount F
5
Bumpy
Qty
1
2
2
2
2