Furuno FCV-600 Installation Manual page 20

Hide thumbs Also See for FCV-600:
Table of Contents

Advertisement

1. MOUNTING
1.3.4
Mounting of 525STID-MSD/525STID-PWD transducers (speed/
temperature sensors)
Note: DO NOT overtighten screws. They may be damaged.
525STID-MSD
The optional transducer 525STID-MSD is designed for thru-hull mounting. For mount-
ing, see section 1.3.1.
525STID-PWD
The optional transom mount transducer 525STID-PWD can be mounted by the thru-
hull method or the inside-hull method.
Tools and materials needed
• Scissors
• Safety goggles
• Electric drill
• Drill bit:3,4,6,9
• Straight edge
• Pencil
• Water-based antifouling paint (mandatory in salt water)
Mounting location
To ensure the best performance, the
sensor must be submerged in aeration-
free and turbulence-free water. Mount
the sensor close to the centerline of the
boat. On slower heavier displacement
hulls, positioning it farther from the cen-
terline is acceptable. Allow adequate
space above the bracket for it to release and rotate the sensor upward. Refer to the
illustration below for dimensions.
φ 79
133 2.00"-12 UN
threads
φ 51
27
140
Triducer 525STID-MSD
• Masking tape
• Dust mask
• Screwdrivers
• Marine sealant
• Cable ties
Height without
speed sensor
191 mm (7-1/2")
Height with
speed sensor
213 mm (8-1/2")
15
BOW
7
Unit: mm
Height

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcv-800

Table of Contents