DC Charger
Remove LOTO actions
CAUTION
Auxiliary supply must be disconnected last and connected first when possible.
Electric shock hazard. Auxiliary supply power layout is a characteristic of each plant and may vary
from one installation to another. Check the latest electrical schematics of the plant and make sure no
voltage is present by confirming with a multimeter.
Electric shock hazard. Wait until all capacitors of the equipment are discharged under 30 V.
Check it with a multimeter.
Before any maintenance operation, verify that the equipment is completely stopped before maneuvering any
cutting element. This applies to elements with load-breaking capacity (circuit breakers and switches) as well as
those with no capacity (disconnectors). Under no circumstances any of these components must be manually
operated when the equipment is energized.
Follow the LOTO actions in the inverse order to remove LOTO actions.
Ford Pro contact info: chargingsupport@fordpro.com and 1-800-34-FLEET