DC Charger

6. CABLE ACCESS AND CONNECTIONS

WARNING
Before opening any door, the equipment must be completely isolated, without any voltage. Make sure
to follow the insulation guidelines and all safety instructions indicated in the
Otherwise, you may get an electric shock. Please use all the indicated PPE.
During the connection, you must ensure the proper cable installation in the terminals of the equipment so that
there are no voltage parts accessible in this wiring and the polarity is respected
CAUTION
To guarantee proper electrical installation, it is very important to comply with the bend radius of the cable. The
installer must ensure that the trenches are deep enough and consistent with the section
NOTICE
Refer to the recommended tightening torque for mechanical and electrical connections in the "
sizing" section.
The manufacturer is not responsible for damages resulting from an incorrect connection.
The dimensioning of the input power cable of the charging point must be checked by a qualified
electrician. The installer is responsible for the correct sizing and execution of the corresponding
connections in accordance with the regulatory requirements applicable in the country of installation.
The installer is responsible for choosing and installing the communication cables.
The installer is responsible for the correct sizing and execution of the corresponding ground networks
in accordance with the regulatory requirements applicable in the country of installation.
Power, ground, auxiliary and communication cables are not included within the manufacturer' scope.
MATERIAL WITHIN INSTALLER'S RESPONSIBILITY:
The following cables and elements are not provided by the manufacturer, they are installer's responsibility.
AC input power cables and terminal lugs (as applicable).
Ground input cable and terminal lug to site local ground system (as applicable).
+/- DC power cables and terminal lugs to each Dispenser or pantograph (as applicable).
Ground cables and terminal lugs to each Dispenser or pantograph (as applicable).
MV switchgear wiring terminals (as applicable).
Control optical fiber to each Dispenser or pantograph (as applicable).
Ethernet cable (CAT5e or CAT6) with RJ45 terminals OR optional multimode optical fiber to each
Dispenser (as applicable).
Several factors can influence the choice of cable, including the distance between the distribution board and the
power cabinet, the maximum input current, and the installation mode.
Ford Pro contact info: chargingsupport@fordpro.com and 1-800-34-FLEET
NB 120 Installation Manual
6
"Safety
instructions" section.
"Site
recommendations".
Torque and screw
EN
31