DC Charger
• Inside the cabinet, every power module has three LED indicators. Picture illustrates LEDs in
the power module when the door is open:
LED
NORMAL
INDICATOR
STATE
FAULT (red)
Off
ALM (yellow)
Off
RUN (green)
On
Ford Pro contact info: chargingsupport@fordpro.com and 1-800-34-FLEET
ABNORMAL
STATE
If ON, it indicates a fault has been triggered in the power module. In that
On
case, the equipment will run without using this power module.
If ON, it indicates a warning has been triggered in the power module. In
that case, the equipment will run without using this power module. If this
warning disappears, the equipment will run using this power module again.
On
The normal status of the "ALM" LED is "Off". When the charger is in stand-
by (no vehicle charging) the LED will flash until vehicle charging begins. At
this point, the LED will no longer be illuminated and will switch to the "Off"
state.
If the "ALM" LED is fix or flashing, this indicates an abnormal state.
Off
If ON, it indicates the power module is being energized.