[When DP junction PWB is used]
13. Fit the mount plate B to the copy guard
PWB using the screw.
14. Insert the FFC into the copy guard PWB
until it clicks in.
WIth a DP junction PWB:
A FFCs is used at YC2 (serigraphed on
MAIN)
YC1 (Serigraphed on DP)
15. IFit the copy guard PWB by hooking to
two hooks of the IH cover and using the
screw.
Y116141-8
FFC(long)
Copy guard PWB
1-2-59
Mount plate B
YC2(MAIN)
YC1(DP)
Figure 1-2-82
Hook
Copy guard PWB
Hook
Figure 1-2-83