Item No.
U101
Setting the voltage for the primary transfer
Description
Sets the control voltage for the primary transfer.
Purpose
To change the setting when any density problems, such as too dark or light, occur.
Method
1. Press the start key.
2. Select the item. The screen for executing each item is displayed.
Base
1st side
2nd side
B/W
Setting: [Base]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
Display
Full
3/4
Half
3. Press the start key. The value is set.
Setting: [1st side/02nd side]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
Display
C
M
Y
K
3. Press the start key. The value is set.
Y116141-8
Display
Standard value
Correction value of single-side printing
Correction value of duplex printing
Correction value of monochrome printing
Full speed printing
3/4 speed printing
Half speed printing
Correction value (Cyan)
Correction value (Magenta)
Correction value (Yellow)
Correction value (Black)
Description
Description
Description
Description
1-3-65
Setting
Initial
range
setting
45
0 to 100
36
0 to 100
25
0 to 100
Setting
Initial
range
setting
5/2
-50 to 50
5/2
-50 to 50
0/-3
-50 to 50
5/2
-50 to 50
Service Manual