12. Open the front cover and then pull out the waste toner box tray (see page 1-5-13).
13. Remove three bandage labels.
14. Rotate the adjustment knob using a 5 mm hex wrench.
Direction of rotation
(V-1 - V-5) >= 2 scales (sample 1): rotate counterclockwise.
(V-1 - V-5) <= -2 scales (sample 2): rotate clockwise.
Number of rotation
(V-1- V-5) x 4 clicks
15. Refit the waste toner box tray as before and then close the front cover.
16. Turn the main power switch off and on. Correction automatically starts.
17. Print a reference chart and verify the result.
Caution
After the adjustment for the abgle of the mirror has been made, run the maintenance mode U464
(Calibration). (see page 1-3-148)