Code
Contents
6720
Belt rotation error (IHPWB)
6730
Abnormally high IGBT1
temperature (IHPWB)
6740
Abnormally high IGBT2
temperature (IHPWB)
6750
Abnormally output overcur-
rent (IHPWB)
6760
Abnormally AC input over-
current (IHPWB)
6770
Abnormally low electric
power (IHPWB)
Service Manual
Causes
Defective PWB.
Replace the IH PWB and check for correct
operation (see page 1-5-51).
Defective fuser
Replace the fuser motor.
motor.
Defective fuser
Replace the fuser unit (see page 1-5-17).
unit.
Defective PWB.
Replace the IH PWB and check for correct
operation (see page 1-5-51).
Defective cooling
Replace the IH fan motor.
fan motor.
Defective PWB.
Replace the IH PWB and check for correct
operation (see page 1-5-51).
Defective cooling
Replace the IH fan motor.
fan motor.
Defective PWB.
Replace the IH PWB and check for correct
operation (see page 1-5-51).
Defective fuser
Replace the fuser unit (see page 1-5-17).
unit.
Defective PWB.
Replace the IH PWB and check for correct
operation (see page 1-5-51).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Defective PWB.
Replace the IH PWB and check for correct
operation (see page 1-5-51).