9. Remove two screws and remove the
DP junction PWB.
10. Pass the FFC through the aperture
section of the controller box.
11. Connect the main-circuit PWB with the
FFC.
Main PWB (YC34)
12. Refit the DP junction PWB cover and
the rear cover.
Service Manual
Controller box
aperture part
FFC
Figure 1-2-80
Copy guard PWB
Figure 1-2-81
1-2-58
Screw
Screw
DP junction PWB
cover
Main PWB
YC34
FFC connector
Y116141-8
2NP