11.1.23

TriggerSource

Specifies the internal signal or physical input Line to use as the trigger source. The selected
trigger must have its TriggerMode set to On.
Name
Category
Interface
Access
Unit
Values
TriggerSource
All
Counter1End
Counter2End
Line0
Line1
Line2
Line3
Line4
Line5
Line6
Line7
Off
Software
11.2

Category: ActionControl (GigE only)

Category containing the Action Control functions.
General Information
The basic idea behind this function was realizing simultaneous trigger for multiple cameras.
For doing so, a broadcast Ethernet package was implemented. This package can act as trigger
or be used for other actions.
The individual network components provide different latencies and jitter, so Ethernet trigger is
not as synchronous as hardware trigger. However, network applications can handle jitter.
Action Command is transmitted as broadcast. Furthermore, several cameras can be grouped to-
gether, so that not each connected camera will respond to Action Commands.
Action Commands include the following information:
Device Key - as device-specific authorization for responding to the Action Command
n
Action ID - as action signal identification
n
Group Key - for action trigger addressing individual device groups
n
Group Mask - to extend the range of individual device groups
n
86
TriggerSource
AcqusitionControl
IEnumeration
Read / Write
-
see table(s) below
VCXG.2