11
|
GenICam Camera Features
Incoming signals
(valid and invalid)
Debouncer
Filtered signal
11.10.1

LineDebouncerHighTimeAbs

Defines the absolute value of the selected line debounce time in microseconds for switching
from low to high.
Name
Category
Interface
Access
Unit
Values
11.10.2

LineDebouncerLowTimeAbs

Sets the absolute value of the selected line debounce time in microseconds for switching from
high to low.
Name
Category
Interface
Access
Unit
Values
132
U
30V
11V
4.5V
0
U
30V
11V
4.5V
0
LineDebouncerHighTimeAbs
DigitalIOControl
IFloat
Read / Write
µs
0.000000 - 5,000.000000 (Increment: 1.00)
LineDebouncerLowTimeAbs
DigitalIOControl
IFloat
Read / Write
µs
0.000000 - 5,000.000000 (Increment: 1.00)