Readoutmode; Shortexposuretimeenable - Baumer CX Series Operating Manual

Table of Contents

Advertisement

Baumer
11.1.15

ReadoutMode

Specifies the operation mode of the readout for the acquisition.
Image acquisition consists of two separate procedures carried out in succession.
Exposing the pixels on the photosensitive surface of the sensor is only the first part of the image
acquisition process. Once this first step is completed, the pixels are read out.
The exposure time (texposure) can be adjusted by the user, however, the time needed for the
readout (treadout) is determined by the particular sensor and image format in use.
Depending on mode and the combined exposure and readout time, the cameras are operated in
Sequential or Overlapped:
Overlapped
In this operation mode, an image is being ex-
posed whilst Frame (n) is being read.
Exposure
Readout
Name
Category
Interface
Access
Unit
Values
11.1.16

ShortExposureTimeEnable

Controls if short exposure time should be supported.
INFO
Sequencer will not be accessible if function ShortExposureTimeEnable is enabled.
Name
Category
Interface
Access
Unit
Values
V1.1 | VCXG.2 / VCXG.2.XC / VCXG.2.I / VCXU.2
n
n
+ x
n
+ 1
e
e
e
n
n
+ 1
r
r
ReadoutMode
AcqusitionControl
IEnumeration
Read / Write
-
Overlapped
Overlapped ReadoutMode.
Sequential
Sequential ReadoutMode.
ShortExposureTimeEnable
AcqusitionControl
IBoolean
Read / Write
-
true = 1 (On)
false = 0 (Off)
GenICam Camera Features
Sequential
Here, the time intervals are long enough for the
exposure and readout to be processed succes-
sively.
n
e
Exposure
n
+ x
r
Readout
Operating Manual
|
11
n
+ 1
e
n
n
+ 1
r
r
83