Table of Contents

Advertisement

Baumer
11.10.3

LineFormat

Controls the current electrical format of the selected physical Input or Output.
LineFormat switchover will adapt the output behavior to the respective system.
INFO
In all modes the supply voltage for the Outputs (Pin 11, 12) must to be connected for function!
Name
Category
Interface
Access
Unit
Values
The following Line Formats are available for each Output:
Line Format
Push-Pull
Open-Source Typical applications for this mode are:
Open-Drain
V1.1 | VCXG.2 / VCXG.2.XC / VCXG.2.I / VCXU.2
LineFormat
DigitalIOControl
IEnnumeration
Read / Write
-
see table(s) below
Description
This mode is used to create steep sharp
edges for dynamic switching operations.
Advantage: Steep flanks in both direc-
tions.
Disadvantage: For long cable more sus-
ceptible to ground bounce and potential
differences.
PLC input, control of illumination con-
nected to ground.
Advantage: Stable at long cable lengths
and potential differences.
Disadvantage: The falling edge has a
lower slope due to parasitic capaci-
tances. Switching off is slower due to
this lower slope.
A typical case of application for this
mode is a illumination control connected
to plus.
Advantage: Stable at long cable lengths
and potential differences.
Disadvantage: The rising edge has a
lower slope due to parasitic capaci-
tances. Switching off is slower due to
this lower slope.
GenICam Camera Features
Circuit
Power (IO)
Camera
Output
I
GND (IO)
Camera
Output
GND (IO)
t
on
Camera
t
off
Operating Manual
|
11
Power (IO)
Camera
Output
I
GND (IO)
Power (IO)
I
SPS
t
off
Power (IO)
I
Output
GND (IO)
t
on
133