Removing A Hinge Receptacle - Fisher & Paykel DCS RGS Series Service Manual

Hide thumbs Also See for DCS RGS Series:
Table of Contents

Advertisement

1.
Remove the oven door (see page 78 for the door re-
moval procedure).
Left
Hinge Receptacles
2.
Remove the lower screw from the hinge receptacle (see
left photo below).
3.
Loosen the top screw on the hinge receptacle and
remove the gasket retainer from the receptacle.
4.
Grasp the center bar on the hinge receptacle to hold
the receptacle in place, and remove the top screw (see
right photo).
Loosen Screw
Gasket
Retainer
Remove Screw
SERVICING THE COMPONENTS

REMOVING A HINGE RECEPTACLE

Right
Remove Top Screw
Hold Receptacle
5.
Rotate the hinge receptacle so that the bottom is out of
the slot, grasp the bottom with your hand, and remove
the receptacle.
55
Grasp Receptacle