REMOVING THE TRANSFORMER & REIGNITION MODULE
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
1.
Turn off the gas and disconnect power to the range.
2.
Loosen, do not remove, the two false handle screws,
and allow the handle to drop down as far as it will go.
False Handle Screws
3.
Remove the valve panel (see page 56 for the proce-
dure).
Transformer Reignition Module
SERVICING THE COMPONENTS
4.
To remove the transformer:
a) Remove the two nuts from the screws and re-
move the two screws from the transformer.
b) Remove the ceramic nuts from the wires, sepa-
rate the wires, and remove the transformer pri-
mary and secondary wires.
c) Remove the nut from the ground screw and
remove the white transformer wire.
Ground Wires
Nut & Screw
3 Ceramic Nuts
36
Transformer
Nut & Screw