SINGLE THERMAL VALVES (N.C.)
(GRIDDLE & GRILL)
Refer to page 62 for the procedure for servicing the single
thermal valves.
1.
Turn off the gas and disconnect power to the range.
2.
Disconnect a wire connector from one of the single
thermal valve terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the two terminals.
The meter should indicate a closed circuit (0 Ω.).
TESTING THE COMPONENTS
WARNING
Electrical Shock Hazard
DUAL THERMAL VALVE (N.C.)
(MAIN OVEN BAKE & IR)
Refer to page 66 for the procedure for servicing the dual
thermal valve.
1.
Turn off the gas and disconnect power to the range.
2.
Disconnect a wire connector from each of the two dual
thermal valve (bake & IR) terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the bake and IR valve
terminals. The meter should indicate a closed circuit (0
Ω.).