Engineering Labels For Power Cables - Huawei NetEngine 8000 F Hardware Manual

Table of Contents

Advertisement

HUAWEI NetEngine 8000 F
Hardware Guide
Content
MDF-MN-B-C
Example of the Label
Figure 4-387
Figure 4-387 Sample label on a user cable
The meaning of the label in

4.2.12.4.5 Engineering Labels for Power Cables

Engineering Labels for DC Power Cables
These labels are affixed to the DC power cables that provide power supply for
cabinets, including the -48 V, PGND, and BGND cables. Here, the DC power cables
also include power cables and PGND cables.
The labels for DC power cables are affixed to one side of the identification plates
on cable ties. For details of the labels, see
Issue 05 (2023-03-31)
Meaning
MN: row
number and
column number
of the MDF
B: row number
of the terminal
device
C: column
number of the
terminal device
shows a sample label on a user cable.
"A01-03-01-01" indicates that the local end of the user cable is connected to
port 1 in slot 1, chassis 03 of the cabinet in row A, column 01 in the
equipment room.
"MDF-G01-01-01" indicates that the opposite end of the user cable is
connected to the terminal in row 01, column 01 of the MDF in row G, column
01 in the equipment room.
Copyright © Huawei Technologies Co., Ltd.
4 Hardware Installation and Parts Replacement
Example
M: The rows of cabinets from front to back
are numbered from A to Z. N: The columns of
cabinets from left to right are numbered
from 01 to 99. For example, G01 is the MDF
of Row G and Column 01.
Ranges from 01 to 99, for example, 01-01.
Figure 4-387
is as follows:
Table
4-88.
715