Power Supply
Model: PWS-1K23A-SQ, 1200 W redundant modules, 80Plus Titanium level
AC Input
100-127 Vac, 9-7.5A, 50-60 Hz
200-240 Vac, 6-5A, 50-60 Hz
+12 V
Max: 66.7 A, Min: 0 A (100 Vac–127 Vac)
Max: 83 A, Min: 0 A (200 Vac–240 Vac)
+5 V standby: Max: 4 A, Min: 0 A
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 60º C (-40º to 140º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Regulatory Compliance
FCC, ICES, CE, UKCA, VCCI, RCM, NRTL, CB
Applied Directives, Standards
EMC/EMI: 2014/30/EU (EMC Directive)
FCC Part 15 Subpart B
ICE-003
VCCI-CISPR 32
AS/NZS CISPR 32
BS/EN55032
BS/EN55035
CISPR 35
EN 61000-3-2
EN 61000-3-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Green Environment:
2011/65/EU (RoHS Directive)
EC 1907/2006 (REACH)
2012/19/EU (WEEE Directive)
Product Safety: 2014/35/EU (LVD Directive)
UL/CSA 62368-1 (USA and Canada)
IEC/BS/EN 62368-1
Perchlorate Warning
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products
containing CR (Manganese Dioxide) Lithium coin cells. "Perchlorate Material-special handling may apply. See
hazardouswaste/perchlorate"