9 Troubleshooting
No.
Description
1
10 Volts low
2
Live zero error
3
No motor
4
Line phase loss
5
DC link voltage high
6
DC link voltage low
7
DC overvolt
8
DC undervolt
9
Inverter overloaded
10
Motor ETR overtemperature
11
Motor thermistor overtemperature
12
Torque limit
13
Overcurrent
14
Ground fault
15
Hardware mismatch
16
Short Circuit
17
Control word timeout
23
Internal Fan Fault
24
External Fan Fault
25
Brake resistor short-circuited
26
Brake resistor power limit
27
Brake chopper short-circuited
28
Brake check
29
Drive overtemperature
30
Motor phase U missing
31
Motor phase V missing
32
Motor phase W missing
33
Soft-charge fault
34
Serial communication fault
35
Out of frequency ranges
36
Line failure
37
Phase Imbalance
39
Heatsink sensor
40
Overload of Digital Output Terminal 27
41
Overload of Digital Output Terminal 29
42
Overload of Digital Output On X30/6
9
42
Overload of Digital Output On X30/7
46
Pwr. card supply
47
24 V supply low
48
1.8 V supply low
49
Speed limit
50
AMA calibration failed
51
AMA check U
nom
52
AMA low I
nom
53
AMA motor too big
54
AMA motor too small
55
AMA parameter out of range
56
AMA interrupted by user
57
AMA timeout
58
AMA internal fault
59
Current limit
60
External Interlock
62
Output Frequency at Maximum Limit
64
Voltage Limit
65
Control Board Overtemperature
66
Heatsink Temperature Low
67
Option Configuration has Changed
68
Safe Stop Activated
69
Pwr. Card Temp
70
Illegal FC configuration
71
PTC 1 Safe Stop
72
Dangerous Failure
73
Safe Stop Auto Restart
76
Power Unit Set-up
79
Illegal PS config
80
Drive Initialized to Default Value
91
Analog input 54 wrong settings
92
NoFlow
93
Dry Pump
94
End of Curve
95
Broken Belt
96
Start Delayed
97
Stop Delayed
98
Clock Fault
Table 9.1: Alarm/Warning code list
9-2
and I
nom
MG.20.T1.22 - VLT
VLT AQUA Low Harmonic Drive Instruction
Warning
Alarm/Trip
Alarm/Trip Lock
X
(X)
(X)
(X)
(X)
(X)
X
X
X
X
X
X
X
X
(X)
(X)
(X)
(X)
X
X
X
X
X
X
X
X
(X)
(X)
X
X
X
(X)
(X)
X
X
(X)
(X)
X
X
(X)
(X)
(X)
(X)
(X)
(X)
X
X
X
X
X
X
X
X
X
X
(X)
(X)
(X)
(X)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1)
X
X
X
1)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
®
is a registered Danfoss trademark
Parameter Reference
6-01
1-80
(X)
14-12
1-90
1-90
X
X
X
X
8-04
14-53
2-13
2-15
X
(X)
4-58
(X)
4-58
(X)
4-58
X
X
5-00, 5-01
5-00, 5-02
5-32
5-33
X
X
X
X
X
X
X
1)
X
X
22-2*
22-2*
22-5*
22-6*
22-7*
22-7*
0-7*
Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AQUA Drive FC 200 and is the answer not in the manual?

Questions and answers

Table of Contents