Danfoss VLT AQUA Drive FC 200 Instruction Manual page 184

Low harmonic drive
Hide thumbs Also See for VLT AQUA Drive FC 200:
Table of Contents

Advertisement

VLT AQUA Low Harmonic Drive Instruction
Manual
Line Power Supply 3 x 380–480 V AC
Typical Shaft output at 400
V [kW]
Typical Shaft output at 460
V [HP]
Enclosure IP21, 54
Output current
Continuous
(at 400 V) [A]
Intermittent (60 sec over-
load)
(at 400 V) [A]
Continuous
(at 460/ 480 V) [A]
Intermittent (60 sec over-
load)
(at 460/480 V) [A]
Continuous KVA
(at 400 V) [KVA]
Continuous KVA
(at 460 V) [KVA]
Max. input current
Continuous
(at 400 V) [A]
Continuous (at 460/480 V)
[A]
Max. cable size,motor
[mm
2
Max. cable size, line power
F1/F2 [mm
Max. cable size, line power
F3/F4 [mm
Max. cable size, load shar-
ing [mm2 (AWG
Max. cable size, brake
[mm
2
Max. external pre-fuses [A]
1
Est. motor power loss at
rated max. load [W]
V, F1 & F2
Est. motor power loss at
rated max. load [W]
V, F1 & F2
Max. added losses of A1
RFI, Circuit Breaker or Dis-
connect, & Contactor, F3 &
F4
Max Panel Options Losses
Weight,
enclosure IP21, IP 54 [kg]
Weight Drive
section [kg]
Weight Filter
section [kg]
Efficiency
Output frequency
Heatsink overtemp. trip
Power card ambient trip
1) For type of fuse, see the section Fuses.
2) American Wire Gauge.
3) Measured using 16.4 ft [5 m] shielded motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and expected to be within +/-15% (tolerance relates to variety in voltage and cable
conditions). Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to the power loss
in the adjustable frequency drive and opposite. If the switching frequency is increased compared to the default setting, the power losses may
rise significantly.LCP and typical control card power consumptions are included. Further options and customer load may add up to 30 W to the
losses. (Though typical, only 4 W extra for a fully loaded control card, or options for slot A or slot B, each.)
Although measurements are made with state of the art equipment, some measurement inaccuracy must be allowed for (+/-5%).
P500
500
650
F17
880
968
780
858
610
621
857
759
(AWG
2)
)]
2
2)
(AWG
)]
8x456
2
(AWG
2)
)]
(8x900 mcm)
2)
)]
(AWG
2)
)
4)
, 400
10647
4)
, 460
9414
963
4)
®
MG.20.T1.22 - VLT
is a registered Danfoss trademark
P560
P630
560
630
750
900
F17
F17
990
1120
1089
1232
890
1050
979
1155
686
776
709
837
964
1090
867
1022
8x150
(8x300 mcm)
8x240
(8x500 mcm)
4x120
(4x250 mcm)
4x185
(4x350 mcm)
1600
12338
13201
11006
12353
1054
1093
400
2009
1004
1005
0.96
0–600 Hz
203°F [95°C]
154.4°F [68°C]
8 General Specifications
P710
710
1000
F17
1260
1386
1160
1276
873
924
1227
1129
8
2000
15436
14041
1230
8-7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AQUA Drive FC 200 and is the answer not in the manual?

Questions and answers

Table of Contents