Quantum SNC 4000 User Manual page 90

Quantum snc 4000: user guide
Hide thumbs Also See for SNC 4000:
Table of Contents

Advertisement

If the Firmware State is anything but Ready, the information output by
CAUTION
this command will be unreliable.
fcShowDevs
The fcShowDevs command displays information about the devices that are accessible from each FC
interface. The display shows the LUN that the SNC 4000 has assigned to each device, the SCSI Channel
that the device is attached to, the actual SCSI ID and LUN of the device, the vendor, product, revision and
serial number of the device.
SNC4000 >fcShowDevs
Targets Visible to Hosts on FC 1:
LUN Chan
Id
-----------------------------------------------------
0
0
0
1
1
6
2
1
1
22
2
2
fcShowNames
The fcShowNames command displays the node and port names (addresses) of the FCs.
Ctlr Id
Indicates the Channel Number for the interface
PCI Addr
The PCI address of the interface, showing bus, device id, and function number.
ISPType
The type of FC Controller, ISP2310.
Node Name
The FC node name for the SNC 4000.
Port Name
The FC port name for the interface.
fcTxDisable [port]
The fcTxDisable command disables a FC port transmitter.
Parameter
Value
Port
1
SNC4000 > fcTxDisable 1
value = 0 = 0x0
fcTxEnable [port]
The fcTxEnable command enables or re-enables a FC port transmitter
Parameter
Value
Port
1
SNC4000 > fcTxEnable 1
value = 0 = 0x0
84
Lun
Vendor
Product
0
ADIC
Scalar SNC
0
ADIC
Scalar 100
0
IBM
ULT3580-TD1
0
IBM
ULT3580-TD1
Meaning
The SNC connection labeled FC1
Meaning
The SNC connection labeled FC1
Rev
SN
413*
601526
100A
ADIC_1_07032002002
22U0
6811088354
22U0
6811085725fcShowNames
Service Port Command Reference

Advertisement

Table of Contents