The IP address of the ADIC Management Console Server - REQUIRED. For more information, see
the ADIC Management Console User's Guide.
The SNC must be booted and its Ethernet Port must be attached to the local area network.
For the position of the Ethernet port on the SNC, see
Figure 9
Ethernet Port on Interface Panel
5
Verify that the Ethernet Link LED, which is the green LED on the left, is on. This LED is a combined link/
activity LED. If the link is up and there is activity, it will blink.
6
If the LED is on, go to
If the LED is not on, proceed to
Continue through
Replacing the SNC
Exit this MAP.
7
Determine the speed of the network, by following the procedure in
If the Health Check generates a trap event code of 115, then the SNC's yellow Speed LED should be on.
Verify that the yellow Speed LED, which is the yellow LED on the right, correctly reflects the speed of
the network.
8
If the yellow Speed LED correctly reflects the speed of the network, go to
If the yellow Speed LED does not correctly reflect the speed of the network, go to
9
Inform the System Administrator that there may be a problem with the Ethernet cable quality, the
intermediate link speeds or interconnect speeds.
If the System Administrator can find no problems with the Ethernet cable quality, the intermediate link
speeds, or interconnect speeds, but the SNC yellow Speed LED does correctly reflect the network
speed, go to
Ethernet MAP
Continue through
Replacing the SNC
Exit this MAP.
10 Remove the Ethernet cable from the SNC Ethernet Port and attach the Ethernet loop back plug.
11 Verify that the Ethernet LEDs are functioning correctly.
If they are, proceed to
SNC 4000 User's Guide
Step
7.
Before Removing or Replacing the SNC
on page 28.
on page 56.
on page 28.
Step
12.
Figure 9
.
on page 28.
Perform Health Check
on page 44.
Step
10.
Step
9.
57