Manifold Absolute Pressure Sensor

•Working principle of manifold absolute pressure sensor
This sensor is used to measure the absolute pressure of air intake manifold, reflect the intake air pressure according to
the difference of resistance, and then calculate the intake air volume in engine combustion chamber through indirect
conversion, and it is also a non-serviceable part.
•Appearance of manifold absolute pressure sensor
•Working environment
Working pressure range: 20-102kPa
Working temperature range: -40-105°C
Relative humidity: 0 -100% RH.
Extreme operating environment: work for 2 hours at the maximum temperature of 125°C
•Storage environment
Storage temperature: -50°C-150°C
•Electric environment
Typical voltage: DC reference voltage of operating sensor circuit is 5±0.1V.
Characteristic curve
3-39