Setting Drive Loop Ids; Setting The Date And Time - ADIC Scalar 100 User Manual

Quantum scalar 100: user guide
Hide thumbs Also See for Scalar 100:
Table of Contents

Advertisement

Setting Drive Loop IDs

Use Drive to set drive Loop IDs. Available Loop IDs are 0 to 15.
Path: Main Menu > More > Setup > Drive > FC
1
From the main menu, select More. Select Setup and then select Drive. Select FC.
2
Use Change Drive to select the drive whose Loop ID you want to set.
3
Select Next twice.
4
Use Up and Down to pick the new Loop ID for that drive.
The CURRENT column displays the current Loop ID. The NEW column displays the new Loop ID. The
control path associated with the drive appears in the Control Path column.
5
Select Next twice.
6
After the dialog box refreshes, the Drives with this ID shows how many other drives use the selected
Loop ID. If it displays NONE, select OK. Otherwise, change the drive Loop ID so that it is unique.
The library resets the Loop IDs of the affected drives.
7
When complete, select OK.

Setting the Date and Time

Use Date/Time to set the library date and time used by the library logs and displayed on the operator panel.
Note that this does not affect the date and time used by the Remote Management Unit (RMU), but does
affect the date and time shown in the logs retrieved by the RMU.
Path: Main Menu > More > Setup > Utils > Date/Time
1
From the main menu, select More. Select Setup and then select Utils. Select Date/Time.
The Date/Time dialog box displays.
2
Do one of the following:
Use Up, Down, and Next to set the values in the DATE and TIME columns. Note that the library
uses a 24 hour clock:
Year: The last two digits of the year.
Month: The month number.
Day: The day.
Hour: The hour. Note that the library uses a 24-hour clock.
Min: The number of minutes past the hour.
72