Measurement example
Figure 163 Code domain power measurement with CDMA OTA signal analyzer
NOTE
You can use the LIMIT hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication.
Setting display
You can view your measurement results in a different view option.
Procedure
1
Press the TRACE/DISPLAY hard key.
2
Press the Code Order soft key, and then select the code order option from the following choices:
–
Hadamard: To assign the number based on Walsh code order and display the measured
code power according to the assigned number in sequence.
–
Bit Reverse: Code number in binary bit is reversed relative to the Hadamard method.
3
Toggle the Base Code Length soft key and select the base Walsh code number: 64 or 128.
Route map
The JD700B Series provides indoor and outdoor mapping function that allows a user to collect data of
points in an indoor or outdoor environment and track the received signals and coverage of RF
transmitters plotting real time directly on top of a loaded floor plan or a map.
Setting measure setup
Procedure
1
If required, connect a GPS receiver to your JD700B series for outdoor mapping.
Indoor mapping does not necessarily need a GPS antenna.
2
Configure test parameters as described in the "Configuring test parameters" on page 297.
3
To load your map file, complete the following steps:
JD700B Series User's Guide
Chapter 10 Using CDMA Signal Analyzer
327