Pdf417 Set Length 1; Pdf417 Set Length 2 - Datalogic PowerScan Series Product Reference Manual

Table of Contents

Advertisement

PDF417

PDF417 Set Length 1

Specifies one of the bar code lengths for "
is the minimum label length if in Variable Length Mode, or the first fixed length if in
Fixed Length Mode. Length includes the bar code's data characters only. Characters can
be set from 0001 to 2,710 characters (pad with zeroes) in increments of 01. Any value
greater than 2,710 will be considered to be 2,710.
See"
Set Length 1" on page 341
Select PDF417 Length 1 Setting
$CP4L1
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.

PDF417 Set Length 2

This feature specifies one of the bar code lengths for "
. Length 2 is the maximum label length if in Variable Length Mode, or the second
232
fixed length if in Fixed Length Mode. Length includes the bar code's check, data, and
full-ASCII shift characters. The length does not include start/stop characters. Characters
can be set from 01 to 2,710 characters (pad with zeroes) in increments of 01. Any value
greater than 2,710 will be considered to be 2,710.
See "
Select PDF417 Length 2 Setting
$CP4L2
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
0001 = Length 1 is 1 Character
Set Length 2" on page 342
Length 2 is 2,710 Characters
PDF417 Length Control" on page 232
for detailed instructions on setting this feature.
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
for detailed instructions on setting this feature.
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
ENTER/EXIT PROGRAMMING MODE
. Length 1
Appendix G, Keypad
represent-
CANCEL
PDF417 Length Control" on page
Appendix G, Keypad
represent-
CANCEL
PRODUCT REFERENCE GUIDE
233

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerscan pbt9600Powerscan pd9600Powerscan pm9600