Datalogic PowerScan PM9600 Series Quick Reference Manual

Industrial cordless handheld area imager bar code reader
Hide thumbs Also See for PowerScan PM9600 Series:

Advertisement

PowerScan™
PM/PBT9600
QUICK REFERENCE GUIDE
Industrial Cordless Handheld
Area Imager Bar Code Reader™

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic PowerScan PM9600 Series

  • Page 1 PowerScan™ PM/PBT9600 QUICK REFERENCE GUIDE Industrial Cordless Handheld Area Imager Bar Code Reader™...
  • Page 2 PowerScan is a trademark of Datalogic S.p.A. and/or its affiliates, regis- tered in the U.S. The Bluetooth word mark and logos are owned by Blue- tooth SIG, Inc and any use of such marks by Datalogic S.p.A and/or its affiliates is under license. All other trademarks and brands are property their respective owners.
  • Page 3: Table Of Contents

    Setting up the Reader............. 5 Charging the Batteries ........... 5 Linking the Reader............6 Link Datalogic RF Devices to Base ........6 Linking to a Bluetooth Adapter in Serial Port Profile (Slave) Mode..................6 Linking to a Bluetooth Adapter in HID Mode ....... 7 Variable PIN Code ..............
  • Page 4 Contents Changing the Batteries ..........33 Battery Safety ............. 34 Hex-Numeric Keypad ..........36 POWERSCAN™ PM/PBT9600...
  • Page 5: End User Software License Agreement

    Datalogic grants to End User, a personal, non-exclusive, non-transfer- able, non sub licensable, revocable, limited license to use the Soft- ware, solely on the Datalogic Product in which it is embedded or for which it is intended for use, in machine-readable form only, solely for End User's internal business purposes.
  • Page 6 End User to promptly pay all (additional) license fees due and any further damages, if any. 2. License Fee License fees shall be due by End User to Datalogic according to the terms provided for in the relevant contract for the purchase of the Datalogic Product.
  • Page 7 EULA BASIS, EXCEED THE PRICE OR FEE PAID BY END USER FOR THE DATALOGIC PRODUCT. UNDER NO CIRCUMSTANCES SHALL DATALOGIC OR ITS LICEN- SORS BE LIABLE TO END USER OR ANY THIRD PARTY FOR LOST PROFITS, LOST DATA, INTERRUPTION OF BUSINESS OR SERVICE, OR FOR ANY OTHER...
  • Page 8 All notices required or authorized under this Agreement shall be given in writing, and shall be effective when received, with evidence of receipt. Notices to Datalogic shall be sent to the attention of Datalogic IP Tech S.r.l., Legal & IP Department, Via San Vitalino 13, 40012 Calderara di Reno (Bolo- gna), Italy, or such other address as may be specified by Datalogic in writ- ing.
  • Page 9: Software Product Policy

    Italy, without regard to the rules governing conflicts of law. Italian Court of Bologna shall have exclusive jurisdiction over all matters regarding this Agreement, except that Datalogic shall have the right, at its absolute discretion, to initiate proceedings in the courts of any other state, country, or territory in which End User resides, or in which any of End User's assets are located.
  • Page 10 EULA POWERSCAN™ PM/PBT9600...
  • Page 11: About The Scanner

    POWERSCAN™ PM/PBT9600 ABOUT THE SCANNER The PowerScan™ PM/PBT9600 is a feature-rich and rug- ged area imager reader. It is offered in several different models to better fit the different needs of each customer. The table below shows the unique features of each model. MODEL TYPE CONNECTIVITY...
  • Page 12: Pm9600 4-Key And 16-Key Models

    The reader can be set up to select and output a subset of data elements from USA Driver License PDF417 bar codes. USA Driver License This feature can be enabled using either Datalogic Aladdin™ Parsing or the bar codes in the USA Driver License Parsing Quick Reference Guide (QRG), available on the Datalogic website.
  • Page 13 About the Scanner The 4-key keyboard has two fully configurable generic Function keys (F1 and F2) and two arrow keys. These keys are fully customizable to perform specific tasks (e.g. scrolling the list of items, navigating menus, etc.). For all related features and how to configure them, refer to the Product Reference Guide.
  • Page 14: Using The Powerscan™ Pm/Pbt9600

    Using the PowerScan™ PM/PBT9600 USING THE POWERSCAN™ PM/PBT9600 The PowerScan™ PM/PBT9600 normally functions by cap- turing and decoding codes. Turn on the scanner by press- ing the trigger for 2 seconds. When the scanner starts up, it vibrates. After the vibration, the trigger can be released and the startup phase ends.
  • Page 15: Setting Up The Reader

    Setting up the Reader SETTING UP THE READER Follow the steps below to connect and get your reader up and communicating with its host. 1. Physically mount the Base station and connect it to the Host as described in the BC9600 Quick Reference Guide.
  • Page 16: Linking The Reader

    NOTE: The PowerScan PM/PBT9600 may get warm during charging: this is normal and does not mean a malfunction. NOTE: Before using the battery, read "Battery Safety" on page 34. Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum performance. LINKING THE READER...
  • Page 17: Mode

    Linking the Reader 1. If using a Bluetooth adapter on the host device, install any driver provided with the adapter. 2. Scan the Link to Host in SPP mode label below to make the scanner visible to the host device. 3.
  • Page 18: Variable Pin Code

    Power Off NOTE: The PowerScan PBT9600 can be set up to authenticate the remote system when connecting, by entering a Bluetooth passkey or a PIN code. If you want to set the security level and authentica- tion options suitable for your application, or when adding new equipment to a system that requires authentication or uses a custom security PIN, please see the PRG for information.
  • Page 19: Selecting The Interface Type

    Selecting the Interface Type SELECTING THE INTERFACE TYPE Upon completing the physical connection between the reader base station and its host, proceed directly to the Interface Selection paragraph below, to program the reader for the interface type it is connected to (for exam- ple: RS-232, USB, etc.).
  • Page 20 Select RS232-WN RS-232 for use with OPOS/UPOS/JavaPOS Select RS-232 OPOS USB Com to simulate RS-232 standard interface Select USB-COM-STD a. Download the correct USB Com driver from www.datalogic.com. USB-OEM USB -OEM (can be used for OPOS/UPOS/JavaPOS) Select USB-OEM POWERSCAN™ PM/PBT9600...
  • Page 21 Configuring the Interface USB FOR TERMINALS USB HID POS Select USB HID POS USB Toshiba TEC Select USB Toshiba TEC USB FOR MAGELLAN SCANNERS USB for Magellans Select USB Magellan Scanners ETHERNET Select Ethernet Interface QUICK REFERENCE GUIDE...
  • Page 22 Configuring the Interface KEYBOARD USB Keyboard with standard key encoding Select USB Keyboard USB Keyboard with alternate key encoding Select USB Alternate Keyboard USB Composite ★ Select USB-Composite ★ Factory setting POWERSCAN™ PM/PBT9600...
  • Page 23: Country Mode

    Country Mode COUNTRY MODE If using one of the Keyboard Interfaces, select the specific country / language supported by the keyboard. Read the ENTER / EXIT code before and after the Country Mode selection. For a complete list of the available country modes, refer to the Product Reference Guide.
  • Page 24 Country Mode COUNTRY MODE (CONTINUED) Country Mode = Denmark Country Mode = France Country Mode = French Canadian Country Mode = Germany Country Mode = Hungary Country Mode = Italy POWERSCAN™ PM/PBT9600...
  • Page 25 Country Mode COUNTRY MODE (CONTINUED) Country Mode = Japanese 106-Key Country Mode = Lithuanian Country Mode = Norway Country Mode = Poland Country Mode = Portugal Country Mode = Romania QUICK REFERENCE GUIDE...
  • Page 26 Country Mode COUNTRY MODE (CONTINUED) Country Mode = Spain Country Mode = Sweden Country Mode = Slovakia Country Mode = Switzerland Country Mode = United Kingdom POWERSCAN™ PM/PBT9600...
  • Page 27: Programming

    The reader is factory-configured with a set of standard default features. Customize your reader using the pro- gramming bar codes available in the PowerScan™ PM/ PBT9600 Product Reference Guide or using Datalogic Aladdin software configurator. Check the corresponding features section for your interface, and also the Data Edit- ing and Symbologies chapters of the PRG.
  • Page 28: Reading Parameters

    Reading Parameters READING PARAMETERS Move the reader toward the target and center the aiming pattern and illumination system to capture and decode the image. See "Using the PowerScan™ PM/PBT9600" on page 4 for more information. The aiming system will briefly switch off after the acquisi- tion time, and if no code is decoded will switch on again before the next acquisition.
  • Page 29 Operating Modes a label does not disable scanning. Double Read Timeout prevents undesired multiple reads while in this mode. The illuminator is always ON and the reader Always On — is always ready for code reading. Double Read Timeout prevents undesired multiple reads. The reader illuminator flashes on and off Flashing —...
  • Page 30 Operating Modes SCAN MODE (CONTINUED) Scan Mode = Trigger Pulse Multiple Scan Mode = Trigger Hold Multiple Scan Mode = Flashing Scan Mode = Always On Scan Mode = Stand Mode Scan Mode= Retained Trigger Hold Multiple POWERSCAN™ PM/PBT9600...
  • Page 31: Set Date And Time (Optional)

    Operating Modes Set Date and Time (optional) 1. Scan the Enter / Exit Programming bar code below to set date and time. ENTER / EXIT PROGRAMMING MODE 2. Scan the Set Date bar code + six digits for Year, Month and Day (YYYYMMDD) from the "Hex-Numeric Key- pad"...
  • Page 32: Technical Specifications

    Technical Specifications TECHNICAL SPECIFICATIONS The following table contains Physical and Performance Characteristics, User Environment and Regulatory infor- mation. PHYSICAL CHARACTERISTICS Color Yellow/Black Height 19.0 cm (7.5'') Dimensions Length 14.0 cm (5.5”) Width 7.9 cm (3.1”) PM96XX w/o display: 425 gr. (14.9 oz.) Weight PM96XX w/display: max 455 gr.
  • Page 33 Technical Specifications ENVIRONMENTAL CHARACTERISTICS Operating -20° to 50° C (-4° to 122° F) Temperature Recharging Recommended 0° to 35° C (32° to 95° F) Temperature Max allowed 0° to 40° C (32° to 104° F) Storage Tempera- -40° to 70° C (-40° to 158° F) ture Humidity 0 to 95% non-condensing...
  • Page 34 Addons, ISBN, ISSN, Code128, EAN128, ISBT128, Code39, Code39 Full ASCII, Code39 CIP, Code 32, Trioptic, Interleaved 2 of 5, IATA, Industrial 2 of 5, Standard 2 of 5, matrix2 of 5, datalogic 2 of 5, follet 2 of 5, Cod- abar, Code11, MSI, Plessey, Code 93, Pharmacode, BC412...
  • Page 35 Technical Specifications RADIO CHARACTERISTICS Star 433 Star 910 BT models models models Frequency 2400 to 2483.5 working 433MHZ 910MHZ center 36.8 kb/s 19.2 kb/s Programma 500 kb/s 500 kb/s ble Speed (default) (default) 180 m (at 500 kb/s) 100 m (at 500 230 m (at 36.8 Typical kb/s)
  • Page 36 Technical Specifications DOF - DEPTH OF FIELD (TYPICAL) Symbology DOF range PM/PBT9600-SR: 5 mils: 6.4-30.9 cm (2.5-12.2 in) 20 mils: 4-103.7 cm (1.6-40.8 in) 40 mils: 5.5-175 cm (2.2-68.9 in) Code 128 PM/PBT9600-HP: 2.5 mils:6.3-11.5 cm (2.5-4.5 in) 5 mils: 3.8-41 cm (1.5-16.1 in) 20 mils: 4-157 cm (1.6-61.8 in) 40 mils: 5.5-242.9 cm (2.1-95.6 in) PM/PBT9600-SR:...
  • Page 37: Led And Beeper Indications

    LED and Beeper Indications LED AND BEEPER INDICATIONS The reader’s beeper sounds and its LED illuminates to indi- cate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The follow- ing tables list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and so may or may not be turned on.
  • Page 38: Troubleshooting

    Troubleshooting TROUBLESHOOTING PROBLEM POSSIBLE SOLUTION POSSIBLE CAUSE Check system power. No power to the Ensure power supply reader. Nothing happens is connected. when the scan button Interface or Ensure all cable is pulled. power cables are connections are loose. secure. Ensure reader is Reader not programmed to read...
  • Page 39: Warranty

    Datalogic, unless otherwise agreed in an applicable writing by Datalogic. Datalogic will not be liable under the warranty if the Product has been exposed or subjected to any: (1) maintenance, repair, installation, han- dling, packaging, transportation, storage, operation or use that is improper or otherwise not in compliance with Datalogic’s instruction;...
  • Page 40: Ergonomic Recommendations

    Technical Support. Reseller Technical Support An excellent source for technical assistance and informa- tion is an authorized Datalogic reseller. A reseller is acquainted with specific types of businesses, application software, and computer systems and can provide individu- alized assistance.
  • Page 41: Cleaning Procedure

    Cleaning Procedure CLEANING PROCEDURE Proper cleaning is needed on the external plastic surfaces and output window to guarantee reliable scanning and charging of the battery. A regular cleaning routine will remove the dust and dirt that may accumulate on the product over time. The main- tenance activity may be repeated more frequently depending on the severity of the environment in which the scanner is used.
  • Page 42: Cleaning Enclosure And Window Surfaces

    Cleaning Procedure NOTE: Disinfectants may be harsh on metal. They are recommended for use only on enclosures. CAUTION: DO NOT spray or pour cleaner directly onto the unit. DO NOT use solutions in their concentrated form. DO NOT use aerosols, solvents or abrasives. DO NOT use paper towels or rough cloths to clean windows.
  • Page 43 Changing the Batteries CHANGING THE BATTERIES 1. Push in and slide the battery lock down to open the battery door, as shown below. 2. Open the battery door and extract the battery. 3. Invert the sequence to insert the battery and lock the battery door.
  • Page 44 Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller. The use of any other power supplies can damage the device and void your warranty. Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite.
  • Page 45 Battery Safety As with other types of batteries, Lithium-Ion (LI) batteries will lose capacity over time. Capacity deterioration is noticeable after one year of service whether the battery is in use or not. It is difficult to precisely predict the finite life of a LI battery, but cell manufacturers rate them at 500 charge cycles.
  • Page 46 Hex-Numeric Keypad HEX-NUMERIC KEYPAD Use the bar codes that follow to enter numbers as you would select digits / characters from a keypad. HEX-NUMERIC KEYPAD POWERSCAN™ PM/PBT9600...
  • Page 47 Hex-Numeric Keypad HEX-NUMERIC KEYPAD (CONTINUED) QUICK REFERENCE GUIDE...
  • Page 48 Hex-Numeric Keypad HEX-NUMERIC KEYPAD (CONTINUED) POWERSCAN™ PM/PBT9600...
  • Page 49 Datalogic S.p.A. and/or its affiliates • Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many coun- tries, including the U.S. and the E.U.

This manual is also suitable for:

Powerscan pbt9600 series

Table of Contents