NF DP420LS Instruction Manual page 86

Programmable ac power source
Table of Contents

Advertisement

-------- Notes ------------------------------------------------------------------------------------------------------------
 The number of times that a particular step is repeated is Jump count +1.
-----------------------------------------------------------------------------------------------------------------------------
 Branch step (Branch1, Branch2)
When the step is under execution or in the hold state, the step to transition when the branching
instruction through panel operation or CONTROL I/O is detected can be specified. There are two
systems of branch instructions (Branch1 and Branch2), and an instruction can be set for each.
-------- Notes ------------------------------------------------------------------------------------------------------------
 Transition using branch is executed immediately after a branching instruction is detected. Step
Time, Stop Phase, and step termination setting are ignored.
-----------------------------------------------------------------------------------------------------------------------------
 Step termination (Step Term)
Specifies the action when the step completes. When [Continue] is selected, transitions to the step of
the next number. When [End] is selected, the sequence is terminated and the execution transitions to
step No. 0 and enter into the stand-by state. When [Hold] is selected, the output at the end of the step
is suspended, and the execution transitions to the step of the next number when Resume instruction
is detected.
-------- Notes ------------------------------------------------------------------------------------------------------------
 When [Step Term] is set to [Hold], the execution enters into hold state before jump. Jumps
when Resume instruction is detected.
 When [Step Term] is set to [Hold], after the jumps repeated for the specified Jump count, the
execution transitions to the step of the next number when Resume instruction is detected in
hold state.
 While in the hold state due to the step termination in a step where step termination phase is
enabled, the execution transitions to Jump-to step or the step of next number when Resume
instruction is detected, after the hold state is kept until Stop Phase.
-----------------------------------------------------------------------------------------------------------------------------
 Step sync code output (Code)
State output to CONTROL I/O connector. Code to output while the execution of the step, which is
specified by 2-bit H/L.
 Start Phase (StartPhs)
Determines the phase of AC waveform of L1 phase when the step starts. The phase when a step
starts in L2 and L3 phase of polyphase system is the addition of the setting value of intra-Step
parameter Phase and the setting value of the step Start Phase.
DP420LS/DP480LS
4.2 Using Sequence Function
67

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp480ls

Table of Contents