 Turning on the AGC function
1. Turn on the output.
2. Open the AGC/Autocal set window. Following two methods are available.
(a) Shortcut operation:
(b) Push the [Misc] soft-key and select [1: AGC/Auto Cal].
3. Use the [Rmt Sense] item to set the Remote sensing function to on or off, if necessary.
When the Remote sensing function is FB, the AGC function cannot be set to ON.
4. In the [AGC] item, select [2: ON]. If the output voltage setting is within the AGC operation
range, the AGC calibration is started when [ON] is selected here.
5. Close the window.
DP420LS/DP480LS
+
4.12 Using AGC Function