Simulation - NF DP420LS Instruction Manual

Programmable ac power source
Table of Contents

Advertisement

11.19 Simulation

This allows you to simulate power line abnormalities, such as blackout, voltage rise, voltage drop,
abrupt phase change, and abrupt frequency change. It can be used only for AC, sine wave, and
AC+DC-INT. Note that it does not support IEC or other standards test. When performing the tests
specified by the standards, use appropriate peripheral equipment. In the polyphase system, only
the balanced mode is available.
Number of memories
Number of steps
Setting range of Step Time
Parameter
Simulation control
DP420LS/DP480LS
Single
5 (non-volatile)
6 (Initial, Normal 1, Trans 1, Abnormal, Trans 2, Normal 2)
0.0010 s to 999.9999 s (0 s is available only for the Transition Step)
Output range
(The above item is common within the Simulation)
AC voltage
Frequency
Waveform (sine wave only)
Start Phase (excluding the Transition Step)
Stop Phase (excluding the Transition Step)
Synchronous step output (2-bit)
Trigger output
Repeat count (1 to 9999 times or infinite)
Initial
Normal1
Trans1
初期
定常1
Trigger setting example
トリガ設定例
Step sync 1 output example
ステップ同期1出力例
Step sync 2 output example
ステップ同期2出力例
Start
Stop
Polyphase system
Abnormal
Trans2
移行1
異常
移行2
11.19 Simulation
Initial
Normal2
定常2
初期
251

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp480ls

Table of Contents