4. Advanced Operation
4.3.4 Process Flow in a Step
Figure 4–14 shows the process flow in one step. The End operation causes the transition as shown in
Figure 4–15.
If the Start Phase is set to ON, the output starts with the set start phase.
ステップ開始位相設定がオンなら,設定された開始位相から
出力を開始します。
During the specified Step Time, output is performed according to the setting.
指定されたステップ時間の間,設定に従い出力します。
If stop phase setting is on, the output state is kept until the step reaches the
ステップ終了位相設定がオンなら,設定された終了位相に達
specified Stop Phase.
するまで出力状態を保持します。
Figure 4-14 Process Flow through Simulation Steps
When simulation stop operation is executed, the execution transitions to Initial
電源変動試験終了操作が行われたら,初期ステップへ移行し
Step.
ます。
4.3.5 Editing Simulation
-------- Notes ------------------------------------------------------------------------------------------------------------
When the power is turned off, edited contents of the simulation are cleared, and all simulations
have the default setting values when it is started next time. To keep the edited contents of
simulation, save them in the Simulation Memory (see 4.3.8).
When a simulation is loaded from memory, the simulation you are editing is discarded.
You can also turn on output on the Simulation Edit View. In this case, the output will be set to
the state set in the initial step when Power Fluctuation Testing was last compiled (see 4.3.7).
-----------------------------------------------------------------------------------------------------------------------------
98
Start
開始
Transitions to the next step
次ステップへ移行
Figure 4-15 Stop Operation
Transitions to the Initial Step
初期ステップへ移行
= End of simulation
=電源変動試験終了
PROGRAMMABLE AC POWER SOURCE