11.1

Output Function

Output function
11.2

Output Range

Output range
11.3

AC/DC Mode

AC/DC mode
AC
AC+DC
DC
DP420LS/DP480LS
Single
Continuous, Sequence, Simulation
Single
100 V range, 200 V range
Single
AC, AC+DC, DC
The signal source and amplification section of this product are AC-coupled, and
the DC component is canceled.
Only the AC output setting of 40 Hz or higher is available.
The signal sources that can be combined are INT, VCA, SYNC, EXT, and ADD.
When the waveform superimposed with DC is amplified using EXT and ADD
(using external signal sources), it may not be an intended output because the DC
component is canceled. In this case, select the AC+DC mode.
The signal source and amplification section of this product are DC-coupled, and
the DC component is also amplified.
The AC and DC output settings of 1 Hz or higher are available.
The signal sources that can be combined are INT, SYNC, EXT, and ADD.
In polyphase system only AC setting is available.
Fixed to this mode in the Simulation.
Select this mode when you want to amplify a signal including DC, to superimpose
DC (DC offset), or output a frequency of 40 Hz or lower. Also select this mode
when the DC component temporally occurs, for example, by sudden change of
voltage or phase.
The signal source and amplification section of this product are DC-coupled.
Only the DC setting is available.
The signal sources that can be combined are INT and VCA.
It is unavailable for the polyphase system.
Polyphase system
Polyphase system
Polyphase system
AC, AC+DC
Description
11.1 Output Function
237