Emerson Rosemount 5402 Reference Manual page 308

Level transmitter, two-wire non-contacting radar
Hide thumbs Also See for Rosemount 5402:
Table of Contents

Advertisement

Reference Manual
00809-0100-4026, Rev KC
Parameter
AMPLITUDE_THRESHOLD_
CURVE
SIMULATION_MODE
SURFACE_SEARCH
SET_EMPTY_TANK
SET_CONSTANT_THRESHOLD
ECHO_UPDATE
ECHO_FOUND_DISTANCE
ECHO_FOUND_AMPLITUDE
ECHO_FOUND_CLASS
ECHO_COMMAND
ECHO_FALSE
VOL_VOLUME_CALC_METHO
D
VOL_IDEAL_DIAMETER
VOL_IDEAL_LENGTH
VOL_VOLUME_OFFSET
VOL_STRAP_TABLE_LENGTH
VOL_STRAP_LEV_1
VOL_STRAP_VOL_1
VOL_STRAP_LEV_2
VOL_STRAP_VOL_2
VOL_STRAP_LEV_3
VOL_STRAP_VOL_3
VOL_STRAP_LEV_4
VOL_STRAP_VOL_4
VOL_STRAP_LEV_5
VOL_STRAP_VOL_5
296
Advanced Configuration Transducer Block
Index
Default value
number
0x00000000(Und
14
efined)
0
15
0x00000000
(0x00000000)
0
0
16
0x00000000(No
17
Action)
0
18
0x00000000
19
(Uninitialized)
20
0
21
0
22
0x00(Unknown)
0x00000000
(Uninitialized)
23
24
0
0x000000fb(Non
25
e)
26
20
27
20
28
0
29
2
30
0
31
0
32
10
33
10
34
0
35
0
36
0
37
0
38
0
39
0
Description
Command. The following sub-elements are
available:
ACTION
VALUE
Simulation of measurement values. The
following sub-elements are available:
ACTION
VALUE
If the device has locked on a false echo, you
can use this function to force the device to
search for the product surface echo within
the whole tank.
Command.
A constant amplitude threshold can be
used to filter out noise.
The following sub-elements are available:
ACTION
VALUE
Tank diameter
Tank length
Volume offset
Number of strap points
Strap value level
Strap value volume
Strap value level
Strap value volume
Strap value level
Strap value volume
Strap value level
Strap value volume
Strap value level
Strap value volume
Advanced Configuration Transducer Block
October 2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5401Rosemount 5400

Table of Contents