Specifications and Reference Data
October 2018
External power supply
The input voltage Ui for Modbus is 8-30 Vdc (max. rating).
Power consumption:
< 0.5 W (with HART address = 1)
< 1.2 W (incl. four HART slaves)
-
HART
+
HART
120 
RS-485 Bus
Signal wiring
Two-wire half duplex RS-485 Modbus. Use shielded twisted
pair wiring, preferably with an impedance of 120 
(typically 24 AWG), in order to comply with EIA-485
standard and EMC regulations.
Ground (common mode) voltage limit
± 7 V
Bus termination
Standard RS-485 bus termination per EIA-485
209
If it is the last
transmitter on the bus,
connect the 120 
termination resistor
Power
supply
A
120 
B
A.1.6 Display and configuration
Integral display (option code M1)
5-digit integral display. The process variables listed in
"Output variables" on page 210
than one variable is chosen, carousel toggling of data is
used. The display also shows diagnostics and error
information.
Remote display
Data can be read remotely by using the Rosemount 751
Field Signal Indicator (see Rosemount 751 Field Signal
Indicator
Product Data
Sheet) for 4-20 mA/HART, or
Rosemount 752 Remote Indicator for F
(see Rosemount 752 F
OUNDATION
Indicator
Product Data
Sheet).
Configuration tools
Emerson Field Communicator (e.g. 375/475 Field
Communicator), Rosemount Radar Master (RRM) software
package (included with delivery of transmitter), Emerson
AMS Device Manager or any other EDDL or enhanced-EDDL
host, or DeltaV or any other DD (Device Description)
compatible host systems. Certificates are available from all
major host system vendors.
Note
DTM™ (compliant with version 1.2 of the FDT
specification) supporting configuration in for instance
Yokogawa Fieldmate/PRM, E+H FieldCare™, and
PACTware™.
Note
To communicate using RRM or AMS Device Manager, a
HART modem is required. The HART modem is available as
an RS232 or USB version (see
Note
The transmitter can be pre-configured by selecting option
code C1 (see
page
231), and sending a complete
Configuration Data Sheet (CDS). The CDS is available at
Emerson.com.
Reference Manual
00809-0100-4026, Rev KC
can be presented. If more
Fieldbus
OUNDATION
Fieldbus Remote
®
/DTM
Table A-10 on page
238).
Specifications and Reference Data

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5401Rosemount 5400

Table of Contents