Viewing Measurement Data In Rrm - Emerson Rosemount 5402 Reference Manual

Level transmitter, two-wire non-contacting radar
Hide thumbs Also See for Rosemount 5402:
Table of Contents

Advertisement

Operation
October 2018
LCD display parameters
Table 6-1. LCD Display Parameters and Presentation on Display
Parameter
Level
Distance
Level Rate
Signal Strength
Volume
Internal Temperature
AOut Current
Percent of Range
Comm Quality
Signal Quality
Surface/Noise
Margin
6.2.3

Viewing measurement data in RRM

To view measurements, such as level, signal strength, etc. in RRM, select the Tools > Device Display
option and select the Level tab:
Figure 6-4. Presentation of Measurement Data in RRM
154
Presentation on
display
Description
LVL
Product level
DST
Distance from the upper reference point to the product
surface
LR
The speed of level movement up or down
AMP
The signal amplitude of the surface echo
Only measurement
Total product volume
unit is shown
ITEMP
Temperature inside the transmitter housing
ANOUT
Analog Output 4 -20 mA current
% RNG
Level value in percent of total measurement range
COM Q
Digital communication signal quality
SIG Q
The signal quality
SNM
The relationship between the surface peak amplitude and the
strongest noise peak amplitude
Reference Manual