3 Configuration Units
One CK3W Unit in the system supplies servo clock and phase clock signals to all the other Units.
The supply-source CK3W Unit must be installed to the CPU Rack.
Connect the Unit with the smallest address value to the CPU Rack because, by default, it is the supply
source of clock signals.
You may specify the Unit with a desired address as the clock supply source by setting the register.
If the Unit that serves as the clock supply source is connected to the Expansion Rack, an error occurs
because the CPU Unit cannot recognize clock signals.
If this error occurs, the Sys.Status register Sys.NoClocks becomes 1.
3-4-5

Terminal Arrangement

This section describes the terminal arrangement of the digital I/O connection terminal block.
CK3W-MD7110
1
19
18
36
No.
Signal
1
IN00
2
IN01
3
IN02
4
IN03
5
IN04
6
IN05
7
IN06
8
IN07
9
V1
10
OUT00
11
OUT01
12
OUT02
13
OUT03
14
OUT04
15
OUT05
16
OUT06
17
OUT07
18
V2
3-52
No.
Signal
19
IN08
20
IN09
21
IN10
22
IN11
23
IN12
24
IN13
25
IN14
26
IN15
27
V1
28
OUT08
29
OUT09
30
OUT10
31
OUT11
32
OUT12
33
OUT13
34
OUT14
35
OUT15
36
G2
CK3M/CK5M Series Programmable Multi-Axis Controller Hardware User's Manual (O036)