Using Twisted or Solid Wires
Wire type
Solid wire
Twisted wire
 Required Tools
Use a flat-blade screwdriver to remove wires.
The recommended screw driver is as follows.
Model
SZF 0-0,4X2,5 Phoenix Contact
 Connecting Ferrules
Insert the ferrule straight into the terminal hole.
It is not necessary to press a flat-blade screwdriver against the release button.
After you make a connection, make sure that the ferrule is securely connected to the terminal
block.
 Connecting Twisted Wires/Solid Wires
Use the following procedure to connect the twisted wires or solid wires to the terminal block.
1
Press a flat-blade screwdriver straight against the release button from the terminal block front.
2
Leave the flat-blade screwdriver pressed against the release button and insert the twisted wire
or the solid wire into the terminal hole.
Insert the twisted wire or the solid wire until the stripped portion is no longer visible, to prevent
shorting.
CK3M/CK5M Series Programmable Multi-Axis Controller Hardware User's Manual (O036)
Conductor cross-sectional area
2
0.14 to 1.5 mm
Manufacturer
Ferrule
Release button
Conductor length
(stripping length)
10 mm
1
Flat-blade screwdriver
5 Wiring
5
5-27