Omron CK3M Seres Hardware User Manual page 274

Programmable multi-axis controller
Table of Contents

Advertisement

Appendices
ID Type
Value (hex)
Instance ID 01
Attribute ID
The attribute IDs for instances are as shown below.
At-
trib-
ute
Parameter name
ID
(hex)
01
Interface Speed
02
Interface Flags
03
Physical Address
04
Interface Counters
In Octets
In Unicast Packets
In NonUnicast
Packets
In Discards
In Errors
In Unknown Protos
Out Octets
Out Unicast Pack-
ets
Out NonUnicast
Packets
Out Discards
Out Errors
05
Media Counters
Alignment Errors
FCS Errors
Single Collisions
Multiple Collisions
A-18
Description
Gives the baud rate for the interface.
Gives the status of the interface.
Gives the MAC address of the interface.
Path to the physical link object
The number of octets received through
the interface.
The number of unicast packets received
through the interface.
The number of packets besides unicast
packets received through the interface.
The number of packets discarded after re-
ceived by the interface
The number of incoming packets that had
errors.
The number of incoming packets that
were of an unknown protocol.
The number of octets sent through the in-
terface.
The number of unicast packets sent
through the interface.
The number of packets besides unicast
packets sent through the interface.
The number of discarded sent packets.
The number of sent packets that had er-
rors.
Media counters for communications ports
Number of frames received that were not
octets in length.
Number of frames received that did not
pass the FCS check.
Number of frames sent successfully with
only one collision.
Number of frames sent successfully with
two or more collisions.
CK3M/CK5M Series Programmable Multi-Axis Controller Hardware User's Manual (O036)
Attrib-
Data type
Value (hex)
ute
Read
UDINT
Current val-
ue
Read
DWORD
*1
Read
ARRAY
Current val-
OF USINT
ue of the
MAC ad-
dress
Read
Struct
---
Read
UDINT
Current val-
ue
Read
UDINT
Current val-
ue
Read
UDINT
Current val-
ue
Read
UDINT
Current val-
ue
Read
UDINT
Current val-
ue
Read
UDINT
0 (always)
Read
UDINT
Current val-
ue
Read
UDINT
Current val-
ue
Read
UDINT
Current val-
ue
Read
UDINT
Current val-
ue
Read
UDINT
Current val-
ue
Read
Struct
---
Read
UDINT
Current val-
ue
Read
UDINT
Current val-
ue
Read
UDINT
Current val-
ue
Read
UDINT
Current val-
ue

Advertisement

Table of Contents