Note 1. R1 Modules (terminals 23/24, 33/34) support an ON-delay time setting using the Function Setup Software for the F3SX (F3SX-CD100-E)
The ON-delay time is factory-set to 0 s (non-delay (instant breaking)).
2. R2 Modules (terminals 23/24, 33/34) support an OFF-delay time setting using the Function Setup Software for the F3SX (F3SX-CD100-E)
The OFF-delay time is factory-set to 0 s (non-delay (instant breaking)).
3. The actual ON-delay time (time from interlock reset until output occurs) and OFF-delay time (time from when input turns OFF until output
turns OFF) is calculated by adding the applicable times shown in the above table to the user-set time.
Example: If the OFF-delay for an F3SX-N-RR2 is set to 0.5 s (500 ms), the actual OFF-delay is 500 + 35 = 535 ms.
Non-delay (Instant Breaking) Models
Model (E Modules)
Relay outputs
ON → OFF
F3SX-E
---
F3SX-E@
35 ms
F3SX-E-@@
35 ms
F3SX-E-@@@
40 ms
F3SX-E-@@@@
45 ms
ON-delay/OFF-delay Time Setting Models
Model (E Modules)
F3SX-ER1 (See note 1.)
F3SX-ER2 (See note 2.)
F3SX-E-@R1 (See note 1.)
F3SX-E-@R2 (See note 2.)
F3SX-E-@@R1 (See note 1.)
F3SX-E-@@R2 (See note 2.)
F3SX-E-@@@R1 (See note 1.)
F3SX-E-@@@R2 (See note 2.)
Note: 1. R1 Modules (terminals 23/24, 33/34) support an ON-delay time setting using the Function Setup Software for the F3SX (F3SX-CD100-E)
The ON-delay time is factory-set to 0 s (non-delay (instant breaking)).
2. R2 Modules (terminals 23/24, 33/34) support an OFF-delay time setting using the Function Setup Software for the F3SX (F3SX-CD100-
E).
The OFF-delay time is factory-set to 0 s (non-delay (instant breaking)).
3. The actual ON-delay time (time from interlock reset until output occurs) and OFF-delay time (time from when input turns OFF until output
turns OFF) is calculated by adding the applicable times shown in the above table to the user-set time.
Example: If the OFF-delay for an F3SX-E-D1D1D1R2 is set to 1 s (1,000 ms), the actual OFF-delay is 1,000 + 45 = 1,045 ms.
Safety Output Monitor (AS1 Terminal: N/E Modules)
The safety output monitor outputs synchronously with the safety
outputs (non-delay (instant breaking)).
Operation Diagram
F3SX safety output
Safety output monitor

Terminal Arrangement

Main Module
A1 T11 T12 T21 T22
Y1
Control circuits
24 VDC
SS1/
A2 SSC AS3 AS2 AS1
EL1
OMRON SCIENTIFIC TECHNOLOGIES, INC.
USA
Tel. 1/888/510-4357
OFF → ON
---
135 ms
135 ms
156 ms
177 ms
Relay outputs
ON → OFF (See note 2.)
OFF → ON (See note 1.)
35 ms
135 ms
35 ms
135 ms
40 ms
156 ms
45 ms
177 ms
Y2
Y3
1
2
3
4
5
6
7
8
SS2/
EL2 FB
9 10 11 12
13
14
15 16
Canada
Tel. 1/866/986-6766
DC solid-state safety output, auxiliary output
ON → OFF
25 ms
25 ms
25 ms
30 ms
35 ms
DC solid-state safety output, auxiliary output
ON → OFF
25 ms
25 ms
30 ms
35 ms
AS1, AS2, and AS3 are not safety outputs and cannot be used to
configure a safety system. Doing so may result in serious injury if the
F3SX or peripheral devices malfunction.
Input Modules
1
2
3
4
5
6
7
8
1
2
3
9 10 11 12
13
14
15 16
9 10 11 12
For the Latest Information
On the Internet: www.sti.com or www.omron.ca
Safety Controllers
OFF → ON
105 ms
105 ms
105 ms
126 ms
147 ms
OFF → ON
105 ms
105 ms
126 ms
147 ms
!WARNING
Relay Output Module
4
5
6
7
8
11
23
33
K1
K2
13
14
15 16
12
24
34
F3SX
EE-99