4.8.3

Rate Limit

Rate Limits features control on a per port basis. Bandwidth control is supported for
the following: Ingress Bandwidth Control, Egress Bandwidth Control and Egress
Queue.
4.8.3.1
Ingress Bandwidth Control
The Ingress Bandwidth Control page allows you to configure the bandwidth control
for a listed port.
To access this page, click QoS > Rate Limit > Ingress Bandwidth Control.
Figure 4.162 QoS > Rate Limit > Ingress Bandwidth Control
The following table describes the items in the previous figure.
Item
Port
State
Rate (Kbps)
Action
Apply
To access this page, click QoS > Rate Limit > Ingress Bandwidth Control.
The following figure displays the Ingress Bandwidth Control Recover Time set-
tings.
Figure 4.163 QoS > Rate Limit > Ingress Bandwidth Control
To access this page, click QoS > Rate Limit > Ingress Bandwidth Control.
The following figure displays the Ingress Bandwidth Control Status settings.
Figure 4.164 QoS > Rate Limit > Ingress Bandwidth Control
4.8.3.2
Egress Bandwidth Control
The Egress Bandwidth Control page allows you to set the egress bandwidth control
for a listed port.
EKI-7720 Series User Manual
Description
Enter the port number for the rate limit setup.
Select Disabled or Enabled to set the port's state status.
Enter the value in Kbps (16 to 1000000) to set as the bandwidth rate
for the selected port.
Select the Ingress port action to be Drop or Shutdown.
Click Apply to save the values and update the screen.