Error Messages - Rancilio EGRO 5511 Technical Manual

Hide thumbs Also See for EGRO 5511:
Table of Contents

Advertisement

EGRO 5511 Manual
PROGRAMMING - ERROR MESSAGES
No.
1
Error in NVRAM
31
Coffee boiler could not be refilled
33
Steam boiler could not be refilled
41
Coffee boiler does not heat up
43
Steam boiler does not heat up
61
No signal from Flowmeter P1
Applicable as from Software Version 1.20
E061 18200
Error-Number
Description
• Switch machine on and off
• Main water supply faucet/ Pump
• Brew valve Y1 does not close
• Flowmeter P1
• Expansion / Non-return valve
• Boiler inlet
• Control system
• Water Supply/Pump pressure too high
• Main water supply faucet/ Pump
• Level sensor B3
• Y3, mechanical or electrical
• Non return valve
• Cable connections B3 to Control J9
• Control system
• Temperature fuse F11
• Semiconductor element K1
• Heater / Connection / X2
• Temperature sensor NTC B1 /
• Connection J11 pin 1/2
• Control system
• Temperature fuse F21
• Semiconductor element K2
• Heater / Connection / X2
• Pressure switch S13
• Control system
• Wall socket connection 1 phase is
• Flowmeter P1
• Expansion or Non-return valve
• Coffee boiler, inlet or outlet
• Piston jammed
• Flow limiter blocked
• Brew valve (Y1)
Number of brew cycles
Source
Pin 4/5
missing
Display
OFF
Yes
--
Yes
Coffee
Yes
Steam
Yes
Coffee
Yes
Steam
Yes
Coffee
Page 36

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents