Notes On The Mechanical Load Of The; Probe; Lateral Loading Capacity (Flexural Strength) Of Coax Probes - Endress+Hauser Levelflex FMP55 Operating Instructions Manual

Foundation fieldbus guided wave radar
Hide thumbs Also See for Levelflex FMP55:
Table of Contents

Advertisement

Levelflex FMP55 FOUNDATION Fieldbus
Endress+Hauser
6.1.3
Notes on the mechanical load of the probe
Tensile loading capacity of rope probes
FMP55
Rope 4mm (1/6") PFA>316
2 kN
Lateral loading capacity (flexural strength) of rod probes
FMP55
Rod 16mm (0.63") PFA>316L
30 Nm
6.1.4

Lateral loading capacity (flexural strength) of coax probes

FMP55
Probe Ø 42.4 mm 316L
300 Nm