Direct current and alternating current Direct current Ground connection A grounded terminal which, as far as the operator is concerned, is grounded via a grounding system. Protective earth (PE) Ground terminals that must be connected to ground prior to establishing any other connections. Endress+Hauser...
1, 2, 3, ... Item numbers A, B, C, ... Views Safety instructions Observe the safety instructions contained in the associated Operating Instructions Temperature resistance of the connection cables Specifies the minimum value of the temperature resistance of the connection cables Endress+Hauser...
For an overview of the scope of the associated Technical Documentation, refer to the following: • W@M Device Viewer (www.endress.com/deviceviewer): Enter the serial number from nameplate • Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2D matrix code (QR code) on the nameplate 1.3.1 Technical Information (TI)
Registered trademark of the FieldComm Group, Austin, Texas, USA Bluetooth® The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Endress+Hauser is under license. Other trademarks and trade names are those of their respective owners. Apple®...
The manufacturer is not liable for damage caused by improper or non-designated use. Clarification of borderline cases: ‣ For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability.
The measuring system meets the legal requirements of the applicable EU Directives. These are listed in the corresponding EU Declaration of Conformity along with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. 2.5.2 EAC conformity The measuring system meets the legal requirements of the applicable EAC guidelines.
• Enter the serial number from the nameplates into the Endress+Hauser Operations App or scan the 2-D matrix code (QR code) on the nameplate with the Endress+Hauser Operations App: all the information for the measuring device is displayed. Endress+Hauser...
Only 33 digits of the extended order code can be indicated on the nameplate. If the extended order code exceeds 33 digits, the rest will not be shown. However, the complete extended order code can be viewed in the operating menu of the device in the Extended order code 1 to 3 parameter. Endress+Hauser...
Pay attention to the center of gravity of the device so that it does not tilt or slip unintentionally. ‣ Follow the safety instructions and transport conditions for devices weighing more than 18 kg (39.6 lbs) (IEC 61010). Endress+Hauser...
Page 16
These cable ties must not be released during transportation or installation of the device to prevent the spacer from sliding at the probe rod. They may only be removed immediately before screwing the process connection flange into place. Endress+Hauser...
Page 17
Levelflex FMP55 HART Storage, transport A0015471 Endress+Hauser...
• Coax probes can be mounted at any distance from the wall. • When mounting outdoors, a weather protection cover can be used to protect the device against extreme weather conditions. • Minimum distance from the end of the probe to the bottom of the vessel: 10 mm (0.4 in) Endress+Hauser...
The probe, electronics and connection cable are mutually compatible and bear a common serial number. Only components with the same serial number may be connected to one another. Endress+Hauser...
Need help?
Do you have a question about the HART Levelflex FMP55 and is the answer not in the manual?
Questions and answers